Features
Silicon strain gauge sensors successfully fieldproven in many thousands of installations.
Simple, elegant sensor packaging, with very few parts achieves exceptionally high reliability.
Transmitter available with traditional or low profile structures (see photos above).
Aluminum housing has durable, corrosion resistant epoxy finish; 316 ss housing also available; both meet NEMA 4X and IP66 ratings.
Can be provided as a sealed measurement system with numerous configurations of direct connect or capillary connected seals available.
SIL2-Certified Transmitter offered as an option.
Optional mounting bracket sets allow pipe, surface, or manifold mounting of transmitter.
Remote configuration with HART communication protocol in a single loop or multidrop mode; or locally via optional LCD indicator.
Multi-marking is available for FM, CSA, and ATEX intrinsically safe installations. The user determines and permanently marks on the data plate the certification to be applied.
User-entered cutoff point from 0 to 20% of maximum flow.
Dual Seal certified by CSA to meet ANSI/ISA 12.27.01-2003 requirements.
Industry standard 316L ss, Co-Ni-Cr, Nickel alloy�¹, Monel, or Tantalum sensor materials, depending on transmitter structure.
Equivalent to Hastelloy�® C. Hastelloy is a registered trademark of Haynes International, Inc
Estimated Lead Time: 8 - 10 Weeks
Shipping Weight: 5 Kg
L-Tyrosine powder, CAS No.60-18-4, non-essential amino acid manufactured by extraction from vegetable protein. Do not use materials of animal origin in L-Tyrosine manufacturing process. L-tyrosine is an important factor in regulating mood. L-tyrosine deficiency can lead to poor mood, low blood pressure and low body temperature and associates with Restless Leg Syndrome. Tyrosine can be used in sports nutrition drink, skin care cosmetics and health foods.
As an experienced L-Tyrosine manufacturer and supplier, we has been supplying and exporting L-Tyrosine for almost 10 years, please be assured to buy from us. Any inquiries about price and the market trend please feel free to contact us, we will reply you within 1 working day.
L-Tyrosine Food grade Specification
Name L-Tyrosine
Chemical Formula C9H11NO3
Appearance Cristal blanco o polvo cristalino
Assay 99.0 100.5%
Transmittance Clear, colorless, 95% min
Loss on drying 0.20% max
Residue on ignition 0.10% max
Other ammoniated Meet with the requirements
Chloride 0.020% max
Sulfate 0.020% max
Ammonium 0.020% max
PH 5.0 â?? 6.5
Specific rotation -11.3 -12.1
Heavy metals 0.0010% max
Arsenic 0.0001% max
Iron(Fe) 0.0010% max
1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse.
2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface.
3. The wiring should be strictly in accordance with the instructions of our company.
4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument.
5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds.
6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct.
7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse.
8.The quality assurance period is 12 months.
Intelligent Operation Method
1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure.
2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation.
3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure.
4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero.
Simulated operation method
1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease)
2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.
The series of pressure transducers use imported high-quality pressure sensors and special integrated modules, through fine temperature, zero, full range, and non-linear compensation to achieve accurate measurement and transmission of pressure changes in liquid, gas, steam and other media.
Technical Index
Measuring medium: liquid, gas, steam
Pressure range: -0.1MPA~0~60MPA
Accuracy grade: ±0.2%FS, ±0.5%FS
Stability: â?¤0.2%FS/year
Temperature drift: â?¤0.02%FS/(range 0~70)
Environment temperature: -20+85
Storage temperature: -20+85
Output signal: 4-20mA or 1-5VDC
Supply voltage: 12-40VDC
Allow overload: two times the quota voltage
Explosiveproof grade: intrinsically safeia II C T6 flameproof dII C T6
Wetware material: 316 stainless steel and 1Gr18Ni9Ti
Shell material: die casting alloy aluminum,surface epoxy spraying
Pressure interface: M20X1.5
Weight: ordinary 0.75kg, with on-site instructions 1kg
Structure Type
x1
Connection
x2x31
x4
The link mode and output signal of the compact tranmitter are as follows:
Two-wire system:
1 Positive power supply
2 Negative power supply
3 Empty
4 Shell
Three wire system:
1 positive power supply
2 Negative power supply (Negative sharing with signals)
3 Signal+
4 Shell
x5
The connection mode of aviation plug transmitter is as follows:
Two-wire system(direct outlet type)
1 Red wire connection positive power supply
2 Black wire connection negative power supply
Notice
1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse.
2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface.
3. The wiring should be strictly in accordance with the instructions of our company.
4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument.
5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds.
6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct.
7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse.
I.Summary:
The LRDG series pressure transmitter use the sensor components with high precision, high stability diffusion silicon segregation type, by amplifying circuit with high reliability and precision temperature compensation, transformed the
*For dangerous and explosive fields and places
*High reliability and anti-interference performance
PTX201 is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam and mild corrosive fluids.
>All stainless steel construction
>Excellent load cycle stability and shock resistance
>4~20 mA, 2-wire output
>Ranges up to 400 barg
>DIN 43650 plug-in connector
>Higher ranges on request
>Integral LED or LCD display
PTX201 is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam and mild corrosive fluids.
>All stainless steel construction
>Excellent load cycle stability and shock resistance
>4~20 mA, 2-wire output
>Ranges up to 400 barg
>DIN 43650 plug-in connector
>Higher ranges on request
>Integral LED or LCD display
A&S Transmitter Co., Ltd. provide all types of Azbil/Yamatake pressure transmitters:
Yamatake Pressure Transmitter AT9000
Advanced Transmitter Model GTX
Examples of model we can offer:
Yamatake Temperature Transmitter ATT60,
Yamatake Temperature Transmitter ATT70,
Yamatake Temperature Transmitter ATT 90,
Yamatake Temperature Transmitter ATT9X,ect.
A&S Transmitter Co., Ltd. provide all types of Yokogawa Pressure Transmitters:
Yokogawa Y/11AL Pneumatic Absolute Pressure Transmitter,
Yokogawa P10 series pneumatic pressure transmitters,
Yokogawa DPharp EJX series pressure transmitters,
Yokogawa DPharp EJA-E series pressure transmitters,
Yokogawa DPharp EJA series pressure transmitters,etc.
Model:
Yokogawa Temperature Transmitter YTA110
Yokogawa Temperature Transmitter YTA310
Yokogawa Temperature Transmitter YTA320
Yokogawa Temperature Transmitter YTA70
Yokogawa Temperature Transmitter YTA50
A&s transmitter co., ltd. Provide all types of fuji pressure transmitter
Fuji pressure transmitter model fkh
Fuji pressure transmitter model fka
Fuji pressure transmitter model fkg
Fuji pressure transmitter model fkp
Fuji pressure transmitter model fkb
Fuji pressure transmitter model fkw
Fuji pressure transmitter model fkc
Fuji pressure transmitter model fkd
Fuji pressure transmitter model fkx
A&s transmitter co., ltd. Provide all types of emerson/rosemount pressure transmitters
Rosemount pressure transmitters 3051cd
Rosemount pressure transmitters 3051cg
Rosemount pressure transmitters 3051ca
Rosemount pressure transmitters 3051tg
Rosemount pressure transmitters 3051ta
Rosemount pressure transmitter 3051s
Rosemount pressure transmitters 3051l
Etc.
Besides rosemount 3051 pressure transmitters, we can also help you with other rosemount transmitters as follows:
Rosemount 2051 pressure transmitters
Rosemount 1151 pressure transmitters
Rosemount 5300 series pressure transmitters
Rosemount 5400 series pressure transmitters
Rosemount 3100 series pressure transmitters
Rosemount temperature transmitters.Etc.
Apt8000 series is a digital pressure transmitter designed for industrial pressure measurement applications.
The apt8000 offer configurations for gauge pressure, absolute pressure and vacuum including integrated solutions for industrial applications.
Features
Updating time of output current in 90 ms
Improved performance, increased accuracy, greater stability
Two years stability of 0.15%
0.075% accuracy
Parameter setting by local keypad or rs485 communication port
4-20 ma output plus direct digital hart communication
Automatic zero calibration by press button
Explosion proof and weather proof housing
Specification
Process fluid:liquid, gas or vapor
Application:absolute pressure, gauge pressure, vacuum
Measuring range:
0 - 10 kpa ~ 0 - 30 kpa ( minimum )
0 - 7 mpa ~ 0 - 32 mpa ( maximum )
Accuracy:+/- 0.075% of span
Working temperature:-25 to +95 deg.C
Max. Pressure:32 mpa
Display:4 digits programmable & 0-100% bargraph
Power supply:13 ~ 38 vdc
Digital communication:hart protocol, rs485
Response time:90 ms
Mounting:direct instrallation or bracket on 2'' pipe
Dimensions:104 mm ( w ) * 158 mm ( h ) * 110 mm ( d )
Weight:1.2 kg
Enclosure:
Ip67 ( standard )
Intrinsically safe eex ia iic t5 ( standard )
Explosion proof ex d iib t5